Diablo Canyon Power Plant

Diablo Canyon Power Plant
Diablo Canyon Power Plant

Diablo Canyon Power Plant
Diablo Canyon Power Plant is located in California
{{{alt}}}
Location of Diablo Canyon Power Plant in California
Coordinates 35°12′39″N 120°51′22″W / 35.21083°N 120.85611°W / 35.21083; -120.85611Coordinates: 35°12′39″N 120°51′22″W / 35.21083°N 120.85611°W / 35.21083; -120.85611
Status Operational
Commission date Unit 1: May 7, 1985
Unit 2: March 13, 1986
Licence expiration Unit 1: November 2, 2024
Unit 2: August 20, 2025
Owner(s) Pacific Gas & Electric
Operator(s) Pacific Gas & Electric
Architect(s) Pacific Gas & Electric
Reactor information
Reactors operational 1 x 1118 MW
1 x 1122 MW
Reactor type(s) Pressurized water reactor
Reactor supplier(s) Westinghouse
Power generation information
Annual generation 18,588 GW·h
Net generation 17,091 GW·h
Website
PG&E Diablo Canyon[dead link]
As of 2011-01-21

Diablo Canyon Power Plant is an electricity-generating nuclear power plant at Avila Beach in San Luis Obispo County, California. The plant has two Westinghouse-designed 4-loop pressurized-water nuclear reactors operated by Pacific Gas & Electric. The facility is located on about 750 acres (300 ha) in Avila Beach, California. Together, the twin 1,100 MWe reactors produce about 18,000 GW·h of electricity annually, supplying the electrical needs of more than 2.2 million people, sent along the Path 15 500-kV lines that connect to this plant. It was built directly over a geological fault line, and is located near a second fault.[1][2][3][4][5]

The plant is located in Nuclear Regulatory Commission Region IV. In November 2009, PG&E applied to the Nuclear Regulatory Commission (NRC) for 20-year license renewals for both reactors.[6]

Contents

Units

Unit One

Unit One is a 1,122 MWe pressurized water reactor supplied by Westinghouse. It went online on May 7, 1985 and is licensed to operate through November 2, 2024.[7] In 2006, Unit One generated 9,944,983 MW·h of electricity, at a nominal capacity factor of 101.2 percent.

Unit Two

Unit Two is a 1,118 MWe pressurized water reactor supplied by Westinghouse. It went online on March 3, 1986 and is licensed to operate through August 20, 2025.[7] In 2006, Unit Two generated 8,520,000 MW·h of electricity, at a capacity factor of 88.2 percent. The plant draws cooling water from the Pacific Ocean, and during heavy storms both units are throttled back by 80 percent to prevent kelp from entering the cooling water intake. The cooling water is used once and is not recirculated but rather returned to the Pacific Ocean at higher temperature.

Earthquake hazard

Diablo Canyon was originally designed to withstand a 6.75 magnitude earthquake from four faults, including the nearby San Andreas and Hosgri faults,[8] but was later upgraded to withstand a 7.5 magnitude quake.[9] It has redundant seismic monitoring and a safety system designed to shut it down promptly in the event of significant ground motion.

History

Pacific Gas & Electric Company went through six years of hearings, referenda and litigation to have the Diablo Canyon plant approved. A principal concern about the plant is whether it can be sufficiently earthquake-proof. The site was deemed safe when construction started in 1968.

However, by the time of the plant's completion in 1973, a seismic fault, the Hosgri fault, had been discovered several miles offshore. This fault had a 7.1 magnitude quake 10 miles offshore on November 4, 1927, and thus was capable of generating forces equivalent to approximately 1/16 of those felt in the 1906 San Francisco earthquake.[10]

The company updated its plans and added structural supports designed to reinforce stability in case of earthquake. In September 1981, PG&E discovered that a single set of blueprints was used for these structural supports; workers were supposed to have reversed the plans when switching to the second reactor, but did not.[11] According to Charles Perrow, the result of the error was that "many parts were needlessly reinforced, while others, which should have been strengthened, were left untouched." [12] Nonetheless, on March 19, 1982 the Nuclear Regulatory Commission decided not to review its 1978 decision approving the plant's safety, despite these and other design errors.[13]

In response to concern that ground acceleration, or shaking, could cause spillage of submerged fuel rod assemblies which, upon exposure to air, could ignite, PG&E and NRC regulators insist that the foregoing scenario is anticipated and controlled for, and that there is no basis to anticipate spillage.[14] Additional seismic studies are in process, however completion of those studies is not a condition precedent to re-issuance of the operating licenses for the two onsite units.[15]

Starting October 22, 2008, Unit 2 was taken offline for approximately two days due to a rapid influx of jellyfish at the intake.[16]

The Nuclear Regulatory Commission's estimate of the risk each year of an earthquake intense enough to cause core damage to the reactor at Diablo Canyon was 1 in 23,810, according to an NRC study published in August 2010.[17][18] In April 2011, in the wake of the Fukushima nuclear incident in Japan, PG&E asked the NRC not to issue license renewals until PG&E can complete new seismic studies, which are expected to take at least three years.[19][20]

Labor

Overall, there are approximately 1200 employees of Pacific Gas and Electric and 200 employees of subcontractors.[21] Several unions represent the workforce at Diablo, among them the International Brotherhood of Electrical Workers and the International Association of Machinists. Control Technicians and electricians who work for Crane Nuclear, one of many subcontractors, are represented by the IBEW Local 1245.[22] 1245 also represents PG&E meter readers, clerical workers, etc.[23] Local 639,which is involved with Diablo but is under "spring outage", also supports solar energy development as part of the overall energy industry portfolio.[24] This outage has been retracted as of June 10, 2011 [25] The outages are routine for maintenance and the complex process of refueling, and created 1,000 temporary jobs, according to PG&E.[26] Other workers are represented by the Plumbers and Pipefitters.[27]

According to a SLO Tribune interview with PG&E's Chris Johns, "tragedy in Japan has prompted more concerns from Diablo Canyon’s 1,800 employees than any other issue, Becker said. Plant managers are holding brown-bag lunch meetings with employees to address those concerns".[28]

DCISC

The Diablo Canyon Independent Safety Committee (DCISC) was established as a part of a settlement agreement entered into in June 1988 between the Division of Ratepayer Advocates of the California Public Utilities Commission (PUC), the Attorney General for the State of California, and Pacific Gas and Electric Company(“PG&E”).

The DCISC consists of three members, one each appointed by the Governor, the Attorney General and the Chairperson of the California Energy Commission. They serve staggered three-year terms. The committee has no authority to direct PG&E personnel.

Emergency planning

The Nuclear Regulatory Commission defines two emergency planning zones around nuclear power plants: a plume exposure pathway zone with a radius of 10 miles (16 km), concerned primarily with exposure to, and inhalation of, airborne radioactive contamination, and an ingestion pathway zone of about 50 miles (80 km), concerned primarily with ingestion of food and liquid contaminated by radioactivity.[29]

The 2010 U.S. population within 10 miles (16 km) of Diablo Canyon was 26,123, an increase of 50.2 percent in a decade, according to an analysis of U.S. Census data for msnbc.com. The 2010 U.S. population within 50 miles (80 km) was 465,521, an increase of 22.4 percent since 2000. Cities within 50 miles include San Luis Obispo (12 miles to city center) and Paso Robles (31 miles to city center).[30]

Emergency sirens were installed when the plant went operational. Federal law requires an early warning system that radiates out 10 miles from any nuclear facility. However, the county siren coverage goes farther, extending from Cayucos in the north down to upper Nipomo to the south. Due to the real threat of a nuclear power-plant all businesses are required to have a siren information sticker in their business generally located with in the restrooms. Schools, government offices, and any other public building will have a PAZ card(Protective Action Zone). These cards show the 12 zones of evacuation with zone one being the plant it self. The cards also show the direction of evacuation on the highways.

Public participation and protest

File:DIABLO PROTEST 4x6 1981.jpg
Abalone Alliance protesters versus Police

Diablo Canyon was built and entered service despite legal challenges and civil disobedience from the anti-nuclear protesters of the Abalone Alliance.[31] Over a two-week period in 1981, 1,900 activists were arrested at Diablo Canyon Power Plant. It was the largest arrest total in the history of the U.S. anti-nuclear movement.[31]

In spring of 2011, State Senator Sam Blakeslee [32] and US Representative Lois Capps [33] both expressed concern for a renewed safety review. Speaking before the Senate Committee on Environment and Public Works, the congresswoman stated that she believed the "Nuclear Regulatory Commission should stay the license renewal process until the completion of independent, peer reviewed, advanced seismic studies of all faults in the area." The Alliance for Nuclear Responsibility began circulating a petition to similar effect,[34] going further and calling for an outright halt to relicensing. An array of San Luis Obispo-based anti-nuclear groups including Mothers for Peace also called for the closure of Diablo Canyon nuclear power plant.[35]

The Alliance for Nuclear Responsibility also works at the level of the California Public Utilities Commission and initiated a letter writing campaign to Governor Jerry Brown, which requests he "instruct the CPUC to rescind the Certificate of Public Convenience and Necessity for ... Diablo Canyon ... and allow them to operate conditionally only under the agreement by the utilities to immediately begin to fully comply with completion of the state-directed AB 1632 [seismic]studies." [36]

Post-Fukushima developments

According to Victor Dricks, senior public affairs officer for NRC Region IV,[37] the Commission conducted a nationwide review of nuclear power plants for their capacity to respond to earthquakes, power outages and other catastrophic events, and Diablo was found to have "a high level of preparedness and strong capability in terms of equipment and procedures to respond to severe events."

On June 2, 2011, the NRC announced that it would delay the environmental part of the relicensing application but that it had completed the safety portion.[38] A few days later, the Atomic Safety Licensing Board indicated that it would defer adjustment of the adjudicatory schedule of the four contentions brought by SLOMFP, a community based organization, accordingly. The ASLB made no findings regarding the merits of the contentions.[39] Both parties to the dispute claim these developments as victories: Pacific Gas and Electric [40] as well as San Luis Obispo Mothers for Peace.[41]

See also

References

  1. ^ Koenen, Leon (2011-03-25). "The Diablo Canyon Nuclear Power Plant, a 48-Year Odyssey | Environment | SoCal Focus". KCET. http://www.kcet.org/updaily/socal_focus/environment/31573-diablo-canyon-nuclear-power-plant.html. Retrieved 2011-06-10. 
  2. ^ "Is Diablo Canyon prepared for possible earthquake? | KSBY.com | San Luis Obispo, Santa Maria, Santa Barbara, Paso Robles". KSBY.com. 2011-03-14. http://www.ksby.com/news/is-diablo-canyon-prepared-for-possible-earthquake-/. Retrieved 2011-06-10. 
  3. ^ "California's Two Nuclear Plants Near Fault Lines, But Chris Wills with the California Geological Survey says the types of faults are different than the ones in Japan. - KTXL". Fox40.com. 2011-03-14. http://www.fox40.com/news/headlines/ktxl-californias-two-nuclear-plants-near-fault-lines-20110314,0,3265997.story. Retrieved 2011-06-10. 
  4. ^ "Newsom: Calif. Wouldn’t Build Diablo Plant Today". Newsmax.com. 2011-03-17. http://www.newsmax.com/InsideCover/Newsom-California-Diablo-canyon/2011/03/17/id/389759. Retrieved 2011-06-10. 
  5. ^ "Is California Underestimating Quake Threat To Nuclear Plants? | Capital Public Radio". CapRadio. 2011-03-25. http://www.capradio.org/articles/2011/03/25/is-california-underestimating-quake-threat-to-nuclear-plants. Retrieved 2011-06-10. 
  6. ^ "Diablo Canyon - License Renewal Application". Operating Reactor Licensing. Nuclear Regulatory Commission (NRC). March 12, 2011. http://www.nrc.gov/reactors/operating/licensing/renewal/applications/diablo-canyon.html. Retrieved 2011-04-19. 
  7. ^ a b "California Nuclear Profile > Diablo Canyon Nuclear Power Plant". Energy Information Administration, U.S. Department of Energy (DOE). September 2010. http://www.eia.gov/cneaf/nuclear/state_profiles/california/ca.html#_ftn1. Retrieved January 21, 2011. 
  8. ^ "Energy: A Nuclear Horror". Time. February 9, 1976. http://www.time.com/time/magazine/article/0,9171,917988,00.html. Retrieved July 14, 2010. 
  9. ^ David Sneed (August 9, 2011). "Diablo Canyon workshop to focus on earthquakes". The San Luis Obispo Tribune. http://www.sanluisobispo.com/2010/08/08/1244213/diablo-canyon-workshop-september.html. 
  10. ^ "Lompoc Earthquake (1927)". Southern California Earthquake Data Center. 2010. http://www.data.scec.org/chrono_index/lompoc.html. Retrieved November 2, 2010. 
  11. ^ Cummings, Judith (October 2, 1981). "Coast A-Plant Construction Error Tied to Missing Guide to Blueprint". The New York Times: p. 14. 
  12. ^ Perrow, Charles, Normal Accidents (New York: Basic Books 1984) ISBN 0465051421 p. 37
  13. ^ "U.S. Won't Review Diablo Plant Decision: Nuclear Board Upholds '78 Approval of Quake Design Standards". Los Angeles Times: p. A35. March 20, 1982. 
  14. ^ "Diablo Canyon Independent Safety Committee’s Evaluation of Pressurized Thermal Shock and Seismic Interactions for a 20-Year License Extension at the Diablo Canyon Nuclear Power Plant". Diablo Canyon Independent Safety Committee. 2011. http://www.dcisc.org/pts-public-release.php. Retrieved March 18, 2011. 
  15. ^ "In The World of Nuclear Power Crisis". Life Magazine: pp. 23–30. May 1979. http://www.mindfully.org/Nucs/TMI-LifeMay79.htm. Retrieved July 14, 2010. 
  16. ^ "Current Event Notification Report". NRC. October 22, 2008. http://www.nrc.gov/reading-rm/doc-collections/event-status/event/2008/20081022en.html#en44588. Retrieved July 14, 2010. 
  17. ^ Dedman, Bill (March 17, 2011). "What are the odds? US nuke plants ranked by quake risk". msnbc.com. http://www.msnbc.msn.com/id/42103936/. Retrieved April 19, 2011. 
  18. ^ http://msnbcmedia.msn.com/i/msnbc/Sections/NEWS/quake%20nrc%20risk%20estimates.pdf
  19. ^ Upton, John (March 17, 2011). "Seismic Uncertainty at Diablo Canyon". The Bay Citizen. http://www.baycitizen.org/pge/story/diablo-canyon/. Retrieved 2011-04-19. 
  20. ^ Casselman, Ben; Stephen Power (April 12, 2011). "Diablo Plant Delays License Bid for Quake Study". The Wall Street Journal. http://online.wsj.com/article/SB10001424052748704529204576257302591577840.html. Retrieved 2011-04-19. 
  21. ^ Public hearing minutes, Santa Barbara Board of Supervisors, Special NRC session of June 16, 2011
  22. ^ http://www.ibew1245.com/Agreements/Crane_Nuclear_2009-2011.pdf
  23. ^ http://www.ibew1245.com/ContractIndex/PT-002-01.htm
  24. ^ http://www.ibew639.org/index.cfm
  25. ^ http://www.pgecurrents.com/2011/06/10/diablo-canyon-power-plant-unit-returns-to-service-after-planned-outage/
  26. ^ More than 1,000 temporary workers – a boost to the local economy – were brought in to work with PG&E employees to replace a portion of the reactor fuel and to perform maintenance and testing on plant system components that are inaccessible during regular plant operations.
  27. ^ http://openjurist.org/874/f2d/816/huhn-ii-v-pullman-power-products-corporation
  28. ^ http://www.sanluisobispo.com/2011/03/17/1525476/pacific-gas-and-electrics-president.html#storylink=mirelated
  29. ^ "NRC: Backgrounder on Emergency Preparedness at Nuclear Power Plants". Nrc.gov. http://www.nrc.gov/reading-rm/doc-collections/fact-sheets/emerg-plan-prep-nuc-power-bg.html. Retrieved 2011-06-10. 
  30. ^ Bill Dedman, Nuclear neighbors: Population rises near US reactors, msnbc.com, April 14, 2011 http://www.msnbc.msn.com/id/42555888/ns/us_news-life/ Accessed May 1, 2011.
  31. ^ a b Wills, John (2006). Conservation Fallout: Nuclear Protest at Diablo Canyon. Reno: University of Nevada Press. ISBN 0874176808. 
  32. ^ "Blakeslee and Rachel Maddow discuss Diablo". Cal Coast News. 2011-03-25. http://calcoastnews.com/2011/03/blakeslee-and-racheal-maddow-discuss-diablo/. Retrieved 2011-06-10. 
  33. ^ April 12, 2011 3:33 PM (2011-04-12). "Capps Testifies Before Senate About Diablo Canyon Safety | Congresswoman Lois Capps, Representing the 23rd District of California". Capps.house.gov. http://capps.house.gov/2011/04/capps-testifies-before-senate-about-diablo-canyon-safety.shtml. Retrieved 2011-06-10. 
  34. ^ http://a4nr.org/wp-content/uploads/2011/04/042211-A4NR-petition.pdf
  35. ^ Hickey, Julia (April 17, 2001). "Anti-nuclear rally at Avila Beach". The Tribune. http://www.sanluisobispo.com/2011/04/16/1565807/anti-nuclear-rally-at-avila-beach.html. 
  36. ^ "a4nr.org". a4nr.org. http://www.a4nr.org./. Retrieved 2011-06-10. 
  37. ^ Dricks, Victor. "The Santa Barbara Independent The Eyes on Diablo". Independent.com. http://www.independent.com/news/2011/may/31/eyes-diablo/?foo#comments. Retrieved 2011-06-10. 
  38. ^ http://pbadupws.nrc.gov/docs/ML1115/ML111530522.pdf
  39. ^ http://pbadupws.nrc.gov/docs/ML1115/ML111580337.pdf
  40. ^ Johns, Chris (2011-06-05). "Viewpoint: PG&E chief says it is committed to safety of Diablo | The Tribune &". Sanluisobispo.com. http://www.sanluisobispo.com/2011/06/04/1629475/viewpoint-pge-chief-says-it-is.html. Retrieved 2011-06-10. 
  41. ^ "— Mothers For Peace". Mothersforpeace.org. http://mothersforpeace.org/. Retrieved 2011-06-10. 

Further reading

External links


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • Diablo Canyon earthquake vulnerability — Diablo Canyon (Nuclear) Power Plant, located on the water s edge in San Luis Obispo County California, was originally designed to withstand a 6.75 magnitude earthquake from four faults, including the nearby San Andreas and Hosgri faults,[1] but… …   Wikipedia

  • Diablo Canyon — may refer to: Diablo Canyon (album), by Outlaws Diablo Canyon Power Plant, California, U.S. Diablo Canyon, a feature of Caja del Rio, a plateau in New Mexico, U.S. See also Canyon Diablo (disambiguation) This disambig …   Wikipedia

  • Conservation Fallout: Nuclear Protest at Diablo Canyon — is a 2006 book by John Wills. Widespread public opposition accompanied the rise of the U.S. nuclear industry during the 1960s and 1970s. In Conservation Fallout, Wills examines one of the most controversial nuclear projects of the period: Pacific …   Wikipedia

  • Trojan Nuclear Power Plant — The Trojan Nuclear Power Plant shortly before demolition Location Columbia County, near Rainier, Oregon, USA Coordinates …   Wikipedia

  • Montague Nuclear Power Plant — The Montague Nuclear Power Plant was to consist of two 1,150 megawatt nuclear reactors to be located in Montague, Massachusetts. The project was proposed in 1973 and canceled in 1980,[1] after $29 million was spent on the project.[2] On 22… …   Wikipedia

  • Cherokee Nuclear Power Plant — The Cherokee Nuclear Power Plant is an uncompleted energy project 10 miles (16 km) outside of Gaffney, South Carolina, United States. In the early 1970s, Duke Power started construction on a three reactor nuclear power plant at the site.… …   Wikipedia

  • Millstone Nuclear Power Plant — Millstone Nuclear Power Plant …   Wikipedia

  • Dresden Nuclear Power Plant — Dresden Generating Station …   Wikipedia

  • Kernkraftwerk Diablo Canyon — Dieser Artikel wurde auf der Qualitätssicherungsseite des Portals Kernenergie eingetragen. Wenn Du Dich mit dem Thema auskennst oder Interesse daran hast, an diesem Artikel zu arbeiten, bist Du herzlich eingeladen, Dich an der Diskussion und… …   Deutsch Wikipedia

  • Crystal River 3 Nuclear Power Plant — Crystal River Nuclear Plant The power plant complex of Crystal River, on the right of the cooling towers is the nuclear reactor (Unit 3) …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”