Flow-FISH

Flow-FISH

Flow-FISH (fluorescent in-situ hybridization) is a cytogenetic technique to quantify the copy number of specific repetitive elements in genomic DNA of whole cell populations via the combination of flow cytometry with cytogenetic fluorescent in situ hybridization staining protocols [Baerlocher GM, Vulto I, de Jong G, Lansdorp PM. Flow cytometry and FISH to measure the average length of telomeres (flow FISH). Nat Protoc 2006; 1:2365–2376.] .----

=Significance=Flow-FISH is most commonly used to quantify the length of telomeres, which are stretches of repetitious DNA (hexameric TTAGGG repeats) at the distal ends of chromosomes [Moyzis, R.K. et al. A highly conserved repetitive DNA sequence, (TTAGGG)n, present at the telomeres of human chromosomes. Proc. Natl. Acad. Sci. USA 85, 6622–6626 (1988).] in human white blood cells, and a semi-automated method for doing so was recently published in Nature Protocols [Baerlocher GM, Vulto I, de Jong G, Lansdorp PM. Flow cytometry and FISH to measure the average length of telomeres (flow FISH). Nat Protoc 2006; 1:2365–2376.] . Telomere length in white blood cells has been a subject of interest because telomere length in these cell types (and also of other somatic tissues) declines gradually over the human lifespan, resulting in cell senescence, apoptosis [Harley, C.B., Futcher, A.B. & Greider, C.W. Telomeres shorten during ageing of human fibroblasts. Nature 345, 458–460 (1990).] , or transformation [Chang, S., Khoo, C.M., Naylor, M.L., Maser, R.S. & DePinho, R.A. Telomere-based crisis: functional differences between telomerase activation and ALT in tumor progression. Genes Dev. 17, 88–100 (2003).] . This decline has been shown to be a surrogate marker for the concomitant decline in the telomere length of the hematopoietic stem cell pool, with the granulocyte lineage giving the best indication, presumably due to the absence of a long lived memory subtype and comparatively rapid turnover of these cells [Rufer N, Brummendorf TH, Kolvraa S, et al. Telomere fluorescence measurements in granulocytes and T lymphocyte subsets point to a high turnover of hematopoietic stem cells and memory T cells in early childhood. J Exp Med 1999; 190:157–167.] .

=The Technique=

Q-FISH to flow-FISH

Flow-FISH was first published in 1998 by Rufer et al. [Rufer, N., Dragowska, W., Thornbury, G., Roosnek, E. & Lansdorp, P.M. Telomere length dynamics in human lymphocyte subpopulations measured by flow cytometry. Nature Biotechnol. 16, 743–747 (1998).] as a modification of another technique for analyzing telomere length, Q-FISH, that employs peptide nucleic acid probes [Egholm, M. et al. PNA hybridizes to complementary oligonucleotides obeying the Watson-Crick hydrogen-bonding rules. Nature 365, 566–568 (1993).] of a 3'-CCCTAACCCTAACCCTAA-5' sequence labeled with a fluorescin fluorophore to stain telomeric repeats on prepared metaphase spreads of cells that have been treated with colcemid, hypotonic shock, and fixation to slides via methanol/acetic acid treatment [Lansdorp, P.M. et al. Heterogeneity in telomere length of human chromosomes. Hum. Mol. Genet. 5, 685–691 (1996).] ( [http://www.bccrc.ca/tfl/research_lansdorp/Protocols.htm protocol available online] ). Images of the resultant fluorescent spots could then be analyzed via a specialized computer program (method and software available from [http://www.flintbox.com the Flintbox Network] ) to yield quantitative fluorescence values that can then be used to estimate actual telomere length. The fluorescence yielded by probe staining is considered to be quantitative because PNA binds preferentially to DNA at low ionic salt concentrations and in the presence of formamide, thus the DNA duplex may not reform once it has been melted and annealed to PNA probe, allowing the probe to saturate its target repeat sequence (as it is not displaced from the target DNA by competing anti sense DNA on the complementary strand), thus yielding a reliable and quantifiable readout of the frequency of PNA probe target at a given chromosomal site after washing away of unbound probe [Lansdorp, P.M. et al. Heterogeneity in telomere length of human chromosomes. Hum. Mol. Genet. 5, 685–691 (1996).] .
----

Innovation

Unlike Q-FISH, Flow-FISH utilizes the quantitative properties of telomere specific PNA probe retention to quantify median fluorescence in a population of cells, via the use of a flow cytometer, instead of a fluorescence microscope [Baerlocher, G.M. & Lansdorp, P.M. Telomere length measurements in leukocyte subsets by automated multicolor flow FISH. Cytometry A 55, 1–6 (2003).] . The primary advantage of this technique is that it eliminates the time required in Q-FISH to prepare metaphase spreads of cells of interest, and that flow cytometric analysis is also considerably faster than the methods required to acquire and analyze Q-FISH prepared slides. Flow-FISH thus allows for a higher throughput analysis of telomere length in blood leukocytes, which are a readily available form of human tissue sample. The most recent versions of the flow-FISH technique include an internal control population of cow thymocytes with a known telomere length detected by TRF or telomere restriction fragment analysis to which the fluorescence of a given unknown sample may be compared. Because cow thymocytes take up LDS751 dye to a lesser extent than their human counterparts, they may be reliably differentiated via plotting and gating the desired populations. Other cell types that have not in the past proven to be good candidates for flow-FISH can be analyzed via extraction of nuclei and performance of the technique on them directly [Wieser, M. et al. Nuclear flow FISH: isolation of cell nuclei improves the determination of telomere lengths. Exp. Gerontol. 41, 230–235 (2006).] .

Why use flow-FISH?

*Highly reproducible results
*Possible to analyze subsets of cells using physical and immunofluorescent markers.
*Better throughput than Q-FISH
*Possible to acquire fluorescence data on thousands of cells

=Published protocol=For complete protocol, please refer to [http://www.nature.com/nprot/journal/v1/n5/full/nprot.2006.263.html#B23| Flow cytometry and FISH to measure the average length of telomeres (flow FISH)]

----


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • Flow cytometry — Analysis of a marine sample of photosynthetic picoplankton by flow cytometry showing three different populations (Prochlorococcus, Synechococcus, and picoeukaryotes) Flow cytometry (abbreviated: FCM) is a technique for counting and examining… …   Wikipedia

  • Fish — are aquatic vertebrate animals that are typically ectothermic (previously cold blooded), covered with scales, and equipped with two sets of paired fins and several unpaired fins. Fish are abundant in the sea and in fresh water, with species being …   Wikipedia

  • Fish ladder — Fishways, most commonly called fish ladders but also known as fish passes and in Australia also referred to as fish steps, are structures on or around artificial barriers (such as dams and weirs) to facilitate diadromous fishes natural migration …   Wikipedia

  • Fish screen — A fish screen is a barrier designed to prevent fish from swimming or being drawn into an aqueduct, cooling water intake, dam, or other diversion on a river, lake, or other waterway where water is taken for human use. Fish screens are typically… …   Wikipedia

  • Fish River Canyon — It is one of the largest canyons in the world (definitely the largest in Africa), as well as the second most visited tourist attraction in Namibia. It features a gigantic ravine, in total about 100 mi (160 km) long, up to 27 km wide and in places …   Wikipedia

  • Fish farming — Intensive koi aquaculture facility in Israel Fish farming is the principal form of aquaculture, while other methods may fall under mariculture. Fish farming involves raising fish commercially in tanks or enclosures, usually for food. A facility… …   Wikipedia

  • Fish diseases and parasites — This gizzard shad has VHS, a deadly infectious disease which causes bleeding. It afflicts over 50 species of freshwater and marine fish in the northern hemisphere.[1] Like humans and other animals, fish suffer from diseases and parasites. Fish… …   Wikipedia

  • Fish counter — Automatic fish counters are automatic devices for measuring the number of fish passing along a particular river in a particular period of time. Usually one particular species is of interest.One important species studied by fish counters are… …   Wikipedia

  • Fish species of Aravaipa Canyon — Aravaipa Creek, a tributary of the San Pedro River that runs through Aravaipa Canyon in southeastern Arizona, is home to seven native fish species, all of which are found naturally in this location.[1] Although each of these species can be found… …   Wikipedia

  • Fish Hook River — Geobox River name = Fish Hook River native name = other name = other name1 = image size = 300 image caption = The Fish Hook River in Park Rapids in 2007 country = United States state = Minnesota region = region1 = district = district1 = city =… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”