Intraoperative monitoring

Intraoperative monitoring

Intraoperative Neurophysiology Monitoring (IONM) is the use of electrophysiological methods (such as EEG, EMG, and evoked potentials) to monitor the functional integrity of neural structures (brain, nerves, spinal cord) during surgery.

The most common applications are in neurosurgery such as spinal surgery; some brain surgeries; carotid endarterectomy; ENT procedures such as acoustic neuroma resection; and peripheral nerve surgery. Motor evoked potentials have also been used in surgery for TAAA (thoracic-abdominal aortic aneurysms).

Intraoperative monitoring is used * to localize neural structures, for example to locate cranial nerves during skull base surgery; * to test function of these structures; and * for early detection of intraoperative injury, allowing for immediate corrective measures.

For example, during any surgery on the thoracic or cervical spinal column, there is some risk to the spinal cord. Since the 1970's, SSEP (somatosensory evoked potentials) have been used to monitor spinal cord function by stimulating a nerve distal to the surgery, and recording from the cerebral cortex or other locations rostral to the surgery. A baseline is obtained, and if there are no significant changes, the assumption is that the spinal cord has not been injured. If there is a significant change, corrective measures can be taken; for example, the hardware can be removed.

More recently, transcranial electric motor evoked potentials (TCeMEP) have also been used for spinal cord monitoring. This is the reverse of SSEP; the motor cortex is stimulated transcranially, and recordings made from muscles in the limbs, or from spinal cord caudal to the surgery. This allows direct monitoring of motor tracts in the spinal cord.

EEG (electroencephalography) is used for monitoring of cerebral function in neurovascular cases (cerebral aneurysms, carotid endarectomy) and for defining tumor margins in epilepsy surgery and some cerebral tumors.

EMG (electromyography) is used for cranial nerve monitoring in skull base cases and for nerve root monitoring and testing in spinal surgery.

ABR (auditory brainstem response, aka BSEP, BSER, BAEP, etc.) is used for monitoring of the acoustic nerve during acoustic neuroma and brainstem tumor resections.

External links

* Medical Societies
** [http://abnm.uchicago.edu/ American Board of Neurophysiologic Monitoring]
** [http://www.asnm.org/ American Society of Neurophysiologic Monitoring]
** [http://www.aset.org The American Society of Electroneurodiagnostic Technologists, Inc.]

* Healthcare facilities
** VIDEO : [of equipement....] http://www.youtube.com/v/tJiWSfO3MTg] ** [http://www.baptistonline.org/facilities/memphis/services/neurology.asp The Neurodiagnostics Laboratory at Baptist Memorial Hospital-Memphis]

* Vendors
** [http://www.rhythmlink.com Rhythmlink International, LLC]
** [http://www.biotronic.com Biotronic]
** [http://www.sentientmedical.com Sentient Medical Systems]
** [http://www.iomsolutions.net IOM Solutions]

* Private Practices
** [http://www.sentientmedical.com Sentient Medical Systems]
** [http://www.impulsemonitoring.com Impulse Monitoring Inc]
** [http://www.accuratemonitoring.net Accurate Monitoring, LLC]
** [http://www.activediagnostics.com Active Diagnostics]
** [http://www.bromedicon.com Bromedicon, Inc.]


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Intraoperative neurophysiological monitoring — (IONM) or intraoperative neuromonitoring is the use of electrophysiological methods such as electroencephalography (EEG), electromyography (EMG), and evoked potentials to monitor the functional integrity of certain neural structures (e.g., parts… …   Wikipedia

  • Intraoperative Wachheit — (engl. Awareness) liegt vor, wenn ein Patient während einer Allgemeinanästhesie (Narkose) seine Umwelt teilweise oder vollständig wahrnimmt oder Aufforderungen aktiv befolgt. Es werden intraoperative Zustände von Wachheit ohne Erinnerung von… …   Deutsch Wikipedia

  • Entropy monitoring — is a relatively new method of assessing anaesthetic depth. It was commercially developed by Datex Ohmeda, now part of GE Healthcare.It relies on a method of assessing the degree of irregularity in electroencephalogram (EEG) signals. The founding… …   Wikipedia

  • Evoked potential — Intervention MeSH D005071 An evoked potential (or evoked response ) is an electrical potential recorded from the nervous system of a human or other animal following presentation of a …   Wikipedia

  • Neuromonitoring — The scientific practice of neuromonitoring takes place in the surgical suite (OR). It aims to 1) reduce the risk to the patient of iatrogenic damage to the nervous system, and/or 2) provide functional guidance to the surgeon. To accomplish this,… …   Wikipedia

  • Clinical neurophysiology — For the journal, see Clinical Neurophysiology (journal). Clinical neurophysiology is a medical specialty that studies the central and peripheral nervous systems through the recording of bioelectrical activity, whether spontaneous or stimulated.… …   Wikipedia

  • Double aortic arch — Classification and external resources DiseasesDB 33811 MedlinePlus 007316 …   Wikipedia

  • Frühe akustisch evozierte Potentiale — (FAEP) sind eine Untergruppe der akustisch evozierten Potentiale. Sie haben ihre elektrische Quelle in der Hörbahn zwischen Hörschnecke, dem Hörnerven bis zu verschiedenen Kerngebieten im Hirnstamm (Oberer Olivenkern (Nucleus olivaris superior)) …   Deutsch Wikipedia

  • Гепарин-индуцированная тромбоцитопения — Схематическое изображение …   Википедия

  • Auditory brainstem response — The auditory brainstem response (ABR) is an auditory evoked potential extracted from ongoing electrical activity in the brain and recorded via electrodes placed on the scalp. The resulting recording is a series of vertex positive waves of which I …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”