The build up of a higher concentration of a drug across a cell membrane due to the pKa value of the drug and difference of pH across the cell membrane is known as ion trapping. Generally speaking, this results in basic drugs accumulating in acidic bodily fluids such as cytoplasm, and acidic drugs to accumulate in basic fluids such as mastitic milk.

Many cells have other mechanisms to pump a drug molecule inside or outside the cell against the concentration gradient, but these processes are active ones, meaning that they require enzymes and consume cellular energy. In contrast, ion trapping does not require any enzyme or energy. It is similar to osmosis in that they both involve the semipermeable nature of the cell membrane.

Life is an acidogenic process, so most of the cells have a more acidic pH inside the cell than outside (gastric mucosal cells being an exception). Therefore basic drugs (like bupivacaine, pyrimethamine) are more ionized inside the cell than outside. Cell membrane is permeable to non-ionized (fat soluble) molecules, ionized (water soluble) molecules cannot cross it easily. Once a non-ionized molecule of a basic drug crosses the cell membrane to enter the cell, it becomes ionized due to the lower pH inside the cell, and thus becomes unable to cross back. Because transmembrane equilibrium must be maintained, another unionized molecule must diffuse into the cell to repeat the process. Thus its concentration inside the cell increases many times that of the outside. The non-ionized molecules of the drug remain in equal concentration on either side of the cell membrane.

The ionization of a molecule depends upon the pH of its solution. In acidic medium, basic drugs are more ionized and acidic drugs are less ionized. The converse is true for acidic drugs. For example, Naproxen is a non-steroidal anti-inflammatory drug that is a weak acid (its pKa value is 5.0). The gastric juice has a pH of 2.0. It is a 3-fold difference (due to log scale) between its pH and its pKa; therefore there is a 1000x difference between the ionized and unionized concentrations. So, in this case for every one molecule of ionized Naproxen, there are 1000 molecules of unionized Naproxen at a pH of 2. [ www.angelfire.com/tx5/scribe2003/scribe/august/F081709.doc] This is why weak acids are better absorbed from the stomach, weak bases from intestine where pH is alkaline. When pH of a solution is equal to pKa of dissolved drug, then 50% of the drug is ionized, another 50% is unionized.

Ion trapping is the reason why basic (alkaline) drugs are secreted into the stomach (for example morphine) [ [http://www.1911encyclopedia.org/Opium Opium - LoveToKnow 1911 ] ] where pH is acidic, and acidic drugs are excreted in urine when it is alkaline. Similarly, ingesting sodium bicarbonate with amphetamine, a weak base, causes better absorption of amphetamine (in stomach) and its lesser excretion (in urine), thus prolonging its actions. Ion trapping can cause partial failure of certain anti-cancer chemotherapies. [cite journal | author = Mahoney BP, Raghunand N, Baggett B, Gillies RJ. | title = Tumor acidity, ion trapping and chemotherapeutics.I Acid pH affects the distribution of chemotherapeutic agents in vitro | journal = Biochem Pharmacol | year=2003 Oct | volume= 1;66(7):1207-18| pmid = 14505800]

ee also

*Osmosis
*Biophysics
*Forced diuresis
*Henderson-Hasselbalch equation

References


Wikimedia Foundation. 2010.

Игры ⚽ Нужно решить контрольную?

Look at other dictionaries:

  • Ion Idriess — Ion Llewellyn Idriess, OBE (20 September 1889, Waverley, New South Wales 6 June 1979, Mona Vale, New South Wales) was a prolific and influential Australian author.cite web | url = http://www.adb.online.anu.edu.au/biogs/A090420b.htm | title =… …   Wikipedia

  • Ion Creangă — Creangă redirects here. For other uses, see Creangă (surname). Ion Creangă Nică al lui Ştefan a Petrei Ion Torcălău Ioan Ştefănescu Born 1837 or 1839 Târgu Neamţ Died …   Wikipedia

  • Ion exchange resin — An ion exchange resin is an insoluble matrix (or support structure) normally in the form of small (1 2 mm diameter) beads, usually white or yellowish, fabricated from an organic polymer substrate. The material has highly developed structure of… …   Wikipedia

  • ION Geophysical — Infobox Company company name = ION Geophysical Corporation company company type = Public (Nasdaq|IO, NYSE|IO) foundation = 1968 location = Houston, Texas key people = Robert P. Peebler (CEO) area served = Global industry = Petroleum products =… …   Wikipedia

  • Quadrupole ion trap — Scheme of a Quadrupole ion trap of classical setup with a particle of positive charge (dark red), surrounded by a cloud of similarly charged particles (light red). The electric field E (blue) is generated by a quadrupole of endcaps (a, positive)… …   Wikipedia

  • Trapped ion quantum computer — A Trapped ion quantum computer is a type of quantum computer. Ions, or charged atomic particles, can be confined and suspended in free space using electromagnetic fields. Qubits are stored in stable electronic states of each ion, and quantum… …   Wikipedia

  • Fourier transform ion cyclotron resonance — Infobox chemical analysis name = Fourier transform ion cyclotron resonance caption =A FTMS instrument at the Pacific Northwest National Laboratory, USA acronym = FTMS, FTICR classification =Mass spectrometry analytes = manufacturers = related =… …   Wikipedia

  • Measurements with Advanced Trapping Systems — MATS is an acronym standing for Measurements with an Advanced Trapping System, which is a Helmholtz research group for young investigators. It is funded by the Helmholtz Association of German Research Centres between the cooperating institutes… …   Wikipedia

  • Electron Beam Ion Source — Eine Electron Beam Ion Trap (EBIT, Elektronenstrahl Ionenfalle) ist eine spezielle Art von Ionenfalle. Dieser Typ Falle eignet sich insbesondere für die Erzeugung und Speicherung hochgeladener Ionen. In ihr werden niedriggeladene Ionen… …   Deutsch Wikipedia

  • Electron Beam Ion Trap — Eine Electron Beam Ion Trap (EBIT) bzw. Elektronenstrahl Ionenfalle ist eine spezielle Art von Ionenfalle. Dieser Typ Falle eignet sich insbesondere für die Erzeugung und Speicherung hochgeladener Ionen. In ihr werden niedriggeladene Ionen… …   Deutsch Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”