The electrolytic detector, or the bare-point electrolytic detector as it was also called, was a type of wet demodulator used in early radio receivers. This form of detector was in extensive use, and was very sensitive and reliable.

History

While working to develop voice transmission, Reginald Fessenden realised that the radio detectors available would not be suitable for his purpose. Although they worked well for receiving the on-off signals of spark gap transmitters, the coherer and related types of detectors were not, in today's terms, "fast" enough for receiving audio signals.

Fessenden developed what he called a barretter detector that would work to receive AM signals, but it was not very sensitive. The barretter used a fine platinum wire, called Wollaston wire, manufactured as a platinum core in a silver sheath that had to be stripped off with acid. In the process of stripping some Wollaston wire, Fessenden left it immersed in acid too long, until only a tip remained in contact with the solution; he noted that it responded well to radio signals being generated nearby, and could be used as new type of detector.

This story was disputed at the time, with credit for the discovery also given to Michael I. Pupin, W. Schloemilch, Hugo Gernsback and others. However, it is apparent that Fessenden was the first to put the device to practical use.

Description

The action of this detector is based upon the fact that if the only the tip of a platinum wire a few thousandths of an inch in diameter is immersed in an electrolyte solution, and a small D.C. voltage bias is applied to the cell thus formed. Platinum is used because other metals are too quickly dissolved in the acid. The resulting bias current decomposes the solution by electrolysis into tiny gas bubbles that cling to the metal point and tend to insulate the metal tip from the solution thus reducing the bias current. An incoming R.F. current can flow better in the direction across the point that makes the point more negative. That recombines the gases and increases point exposure to the liquid. RF current flow in the direction that makes the point more positive only reinforces gasius blocking of the point. Detection results from this asymmetrical flow.

In practical use a series circuit is made of the detector, headphones, and a battery with a potentiometer. The wire is made positive, and the signal to be demodulated is applied directly to it; a small (about 5 ml) platinum cup filled with either sulfuric or nitric acid completes the headphone circuit, and is also connected to ground to complete the signal circuit. To adjust the cell, the point of the wire electrode is dipped into the electrolyte and the potentiometer adjusted until a hissing noise is heard in the headphones; the potentiometer is then moved back until the noise just ceases, at which point the detector is in its most sensitive state.

It was found that strong atmospheric noise would render it insensitive, requiring that the device be rebiased after each strong burst of static interference.

Sealed-point detector

Another form of electrolytic detector, the sealed-point electrolytic detector, which could stand considerable rough usage, was commercially known as the Radioson Detector; it had the cell sealed in a glass envelope. The operation was the same as in the bare-point electrolytic detector, the advantage being that the acid was sealed in, and consequently could not spill or evaporate.

External links

* [http://home.luna.nl/~arjan-muil/radio/history/wireless-age/electrolytic.html Detectors of electrical oscillations]
* [http://www.northwinds.net/bchris/define.htm Tech Definitions - Radio Concepts]
* [http://earlyradiohistory.us/index.html United States Early Radio History]


Wikimedia Foundation. 2010.

Игры ⚽ Поможем решить контрольную работу

Look at other dictionaries:

  • Detector (radio) — Passband modulation v · d · e Analog modulation AM · …   Wikipedia

  • Cat's-whisker detector — Galena cat s whisker detector Precision cat s whisker d …   Wikipedia

  • Flame ionization detector — A flame ionization detector (FID) is a type of gas detector used in gas chromatography. The first flame ionization detector was developed in 1957 by scientists working for the CSIRO in Melbourne, Australia.… …   Wikipedia

  • Reginald Fessenden — Infobox Celebrity name = Reginald Fessenden caption = The Father of Radio Broadcasting birth date = birth date|1866|10|6|mf=y birth place = East Bolton, Quebec, Canada death date = death date and age|1932|7|22|1866|10|6|mf=y death place = Bermuda …   Wikipedia

  • Hot wire barretter — The hot wire barretter was a demodulating detector invented in 1902 by Reginald Fessenden that found limited use in early radio receivers. In effect it was a highly sensitive thermoresistor developed to permit the reception of amplitude modulated …   Wikipedia

  • Crystal radio — Crystal set redirects here. For the Australian rock band, see The Crystal Set. A modern reproduction of an antique crystal set. It is tuned to different stations by moving the sliding contact (right) up and down the tuning coil (red). The device… …   Wikipedia

  • De Forest, Lee — born Aug. 26, 1873, Council Bluffs, Iowa, U.S. died June 30, 1961, Hollywood, Calif. U.S. inventor. He had invented many gadgets by age 13, including a working silverplating apparatus. After earning a Ph.D. from Yale University, he founded the De …   Universalium

  • Coherer — Metal filings coherer The coherer was a primitive form of radio signal detector used in the first radio receivers during the wireless telegraphy era at the beginning of the twentieth century. Invented around 1890 by French scientist Édouard… …   Wikipedia

  • Wollaston wire — is an obsolete name for very fine (less than .01 mm thick) platinum wire clad in silver used for electrical instruments around the turn of the 19th century. The term Wollaston wire does not clearly distinguish the bare platinum wire from the… …   Wikipedia

  • Gustave-Auguste Ferrié — Infobox Scientist name = Gustave Ferrié caption = birth date = birth date|1868|11|19 birth place = Saint Michel de Maurienne, Savoie death date = death date and age|1932|2|16|1868|11|19 death place = residence = France nationality = French field …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”