Nociception assay

Nociception assay

A Nociception assay (nocioception or nocioperception assay) evaluates the ability of an animal, usually a rodent, to detect a noxious stimulus such as the feeling of pain, caused by stimulation of nociceptors. These assays measure the existence of pain through behaviors such as withdrawal, licking, immobility, and vocalization. The sensation of pain is not a unitary concept; therefore, a researcher must be conscious as to which nociception assay to use.

Contents

Formalin

The formalin assay is the most popular chemical assays of nociception. It entails the injection of a dilute solution of formalin into the surface of the rodent's hindpaw, followed by the scoring of stereotypical behaviors such as flinching, licking, and biting of the affected hindpaw.[1] The behaviors last for approximately 1 hour, with the early or acute stage (directly after injection) reflecting direct activation of nociceptors and the late or tonic phase (15 to 20 minutes after the injection) reflecting tissue damage as a result of inflammation .[1] Typically, the formalin assay is used on rats; however, formalin concentrations and scoring methods can be modified as to accommodate a mouse.[2] One major advantage of the formalin assay over other models of inflammatory pain is the limited duration (approximately 1 hour) of the response.[2] Additionally, as described before, this assay produces a response in two discrete stages, allowing researchers to model both acute and tonic pain using a single noxious chemical.

Von Frey

Shows a Von Frey hair being aimed at a rodents hindpaw.

The Von Frey assay, introduced by Maximilian von Frey and modified by Weinstein, uses Von Frey hair or fibers, which are fine-gauge metal wires, to test a rodent’s sensitivity to pinch and mechanical stimuli .[1] It is unclear whether the process is really considered noxious versus simply annoying, so this assay is a test of mechanical nociception or simply mechanical sensibility. In this test, the animal stands on an elevated mesh platform, and the Von Frey hairs are inserted through the mesh to poke the animal’s hindpaw.[2] Normal reactions for the animal include withdrawing or licking the paw, and possible vocalization, but these can depend on variability within the experiment. For example, the ventral surface of the hind paw is typically associated with lower withdrawal thresholds compared to the dorsal surface, and the exact force of the fiber is determined by its thickness.[2] It is also important to note that thresholds usually are initially decreasing during successive tests, but do become stable after about 3 sessions. Alternatively, automated von Frey systems have recently been discovered that gradually increase the force of a single fiber so that a researcher can observe when withdrawal responses occur.

Thermal Assays

Sensitivity to acute thermal stimulation is the most common test used in live species pain research.[2] The behavioral reflex evoked by noxious heat stimuli is a relatively good predictor of pain sensitivity and its reduction through various analgesics. One significant limitation of thermal assays lies in the specificity and validity of results in animals as models of human pain.[2] Very little is known about the functional mechanics of nociceptive afferents in murine subjects, thus the translation of any pain response observed from these animals to humans is questionable.[2]

Tail Withdrawal

Two versions of the tail withdrawal assay are commonly employed in pain sensitivity testing.[2] In the classic radiant heat test, a heat source is targeted onto a small area of the tail, and the latency to withdraw the tail away from the heat source is measured. In the tail-immersion test, a container of liquid is heated or cooled to a nociceptive temperature – normally 50-55°C or below 0°C. The animal subject is then placed with its tail immersed in the liquid, and the latency to withdraw the tail from the liquid is measured.

Animal subjects used must be restrained to a fairly high degree when performing the tail withdrawal test due to the exact positioning necessary to direct the noxious stimuli. Restraint is usually accomplished by placing the subjects in small Plexiglas tubes or cloth/cardboard pockets that the subjects can either be habituated to or voluntarily enter.[2]

The primary advantage of tail withdrawal assays to other forms of thermal nociception testing, such as the Hot-Plate Test or Hargreaves test, is the relative stability of results with repeated observations. Pain-reflex latency observations from other tests are usually much more variable both across and within subjects than those obtained from the tail withdrawal assay.

Hot Plate

An example of a Hot Plate assay being performed on a mouse.

A heat-conductive surface, such as porcelain or metal, is heated to a temperature that will induce a nociceptive response in an animal subject - normally 50-56°C.[2] The subject is then placed onto the surface and prevented from leaving the platform by blockades. The latency to pain-reflex behavior is measured.[1] One complication of this assay is its unsuitability for repeated testing. Animals that have been subjected to the hot-plate test in the past display a behavioral tolerance phenomenon, which is characterized by decreased latencies and reduced sensitivities to antinocioceptive agents.[1] Another complication of the hot-plate test is determining what constitutes a behavioral pain response; is it the lifting/licking of paws, vocalization, attempting to climb out of the cylinder, etc.[2] Also, delivering the heat stimulus in a controlled fashion presents difficulties due to each section having varying temperatures based upon surface area exposure and whether the animal is moving or not.[2]

Tail Flick

An example of a traditional set-up for the tail flick assay.

The tail flick assay or tail flick test uses a high-intensity beam of light aimed at a rodent’s tail to detect nociception .[1] In normal rodents, the noxious heat sensation induced by the beam of light causes a prototypical movement of the tail via the flexor withdrawal reflex.[2] An investigator normally measures the time it takes for the reflex to be induced, a factor influenced by a rodent’s sex, age and body weight .[1] The most critical parameter for the tail flick assay is the beam intensity; stimuli producing latencies of larger than 3–4 seconds generally create more variable results.[3] Another important factor to consider is the level of restraint used; rodents held too tightly may exhibit greater tail flick latencies due to heightened stress levels.[3]

Hargreaves

The Hargreaves assay uses a high-intensity beam of light directed at the hindpaw rather than the tail to induce pain; an investigator then measures the time it takes for the animal to withdraw its hindpaw .[1] In contrast to the tail flick assay, rodents are often unrestrained while the radiant heat source is focused on the hindpaw. Cut-off latency for the Hargreaves assay is commonly set at 10 seconds .[4] The main advantage of this test over the tail flick assay is that it allows independent assessment of treatment effects on both sides of the body.[2]

Applications

One of the most common applications of nociception assays is to test the effectiveness of new pain medications and drugs of the like. One can then perform comparative tests to measure the differences in the effects of the drug on varying populations, such as men versus women, or young versus old. These tests can also identify certain harmful diseases or abnormalities in subjects if they display atypical nociception test responses. Additionally, nociception tests can be used to test the heritability of nociception itself, as demonstrated by Lariviere et al. One can also use nociception assays to assess the physiology of the “pain” pathway. For example, Caterina et al. tests whether the capsaicin receptor plays a large role in the “pain” pathway by comparing results from nociception assays in mice with and without the receptor. In addition, they are useful in many other tests to make sure subjects have “normal” nociception responses to account for possible extenuating circumstances that would affect other results.

See also

References

  1. ^ a b c d e f g h Carter, M., & Jennifer Shieh. (2010). Animal Behavior. In Guide to Research Techniques in Neuroscience (pp. 51-52). Burlington, MA: Academic Press.
  2. ^ a b c d e f g h i j k l m n Mogil, J. S., Wilson, S. G., & Wan, Y. (n.d.). Assessing nociception in murine subjects. In L. Kruger (Ed.), Methods in pain research (pp. 1-29). (Original work published 2001) Retrieved from http://www.crcnetbase.com/doi/pdf/10.1201/9781420042566-c2
  3. ^ a b Malmberg, Annika B, and Anthony W Bannon. "Models of Nociception: Hot-Plate, Tail-Flick, and Formalin Tests in Rodents." Current Protocols in Neuroscience. N.p.: John Wiley & Sons Inc., 1999. 8.9.1-8.9.15. Print.
  4. ^ Varnado-Rhodes, Yael, et al. "Mu Opioid Analgesia and Analgesic Tolerance in Two Mouse Strains: C57BL/6 and 129/SvJ." Proc. West. Pharmacol. Soc. 43 (2000): 15-17. Print

External links


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • Clinical Neurochemistry — Progression of Huntington s Diesase. A microscope image of Medium spiny neurons (yellow) with nuclear inclusions (orange), which occur as part of the disease process. Clinical Neurochemistry is the field of neurological biochemistry which relates …   Wikipedia

  • List of unusual units of measurement — For units of measure primarily used in countries where English is not the main language, see the article specific to that country, a list of which can be found in the systems of measurement article. An unusual unit of measurement is a unit of… …   Wikipedia

  • Proglumide — Drugbox IUPAC name = 4 (benzoylamino) 5 (dipropylamino) 5 oxopentanoic acid CAS number = 6620 60 6 ATC prefix = ATC suffix = PubChem = 4922 DrugBank = C=18|H=26|N=2|O=4 molecular weight = 334.41 g/mol bioavailability = protein bound = metabolism …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”