AFR sensor

AFR sensor

Articleissues
cleanup=August 2008
wikify=August 2008
copyedit=August 2008
inappropriate tone=August 2008
jargon=August 2008
orphan=August 2008
The AFR is a new type of Oxygen Sensor that is slowly replacing the Zirconium O2 sensor in modern vehicles. Fact|date=August 2008

Theory of Opperation

The early introduction of the oxygen sensor came about in the late 1970’s. Since then Zirconium has been the material of choice for its construction. The Zirconium O2 sensor produces its own voltage, which makes it a type of generator. The generated varying voltage shows up on the scope as the familiar 1 Hz sine wave, when in close loop. The actual voltage that is generated is the difference between the O2 content of the exhaust and that of the surrounding ambient air. The stoichiometric air/fuel ratio or the mixture of air-to-fuel equal to 14.7:1 is the best mixture ratio for gasoline engines. At this ratio, the combustion process happens with the most power being generated and the least amount of emissions being produced. At a stoichiometric air/fuel ratio (14.7:1), the generated O2 sensor voltage is about 450 mV. The ECM recognizes a rich condition above the 450 mV level and a lean condition bellow it. Therefore, these sensors do not care about the air/fuel ratio above or bellow stoichiometry or 14.7-parts-of-air to 1-part-of-fuel. It is for this reason that the Zirconium O2 sensor is called a “narrow band” O2 sensor.

The Titanium O2 sensor was used throughout the late 1980’s and early 1990’s on a limited basis. This sensor’s semi-conductor construction makes its operation different than the Zirconium O2 sensor. Instead of generating its own voltage, the Titanium O2 sensor’s electrical resistance changes according to the exhaust oxygen content. When the air/fuel ratio is rich, the resistance of the sensor is around 950 Ohms and more than 21 K-Ohms when the mixture is lean. As with the Zirconium sensor, the Titanium O2 sensor is also considered a narrow-band O2 sensor.

As mentioned before, the main problem with any narrow band O2 sensors is that the ECM only knows that the mixture is slightly richer or leaner than 14.7:1. The ECM has absolutely no idea as to the operating A/F ratio outside the stoichiometric range. In effect it only knows that the mixture is richer or leaner then stoichiometry. An O2 sensor voltage that goes lower than 450 mV will cause a widening of injector pulse and vise-versa. The resulting changing or cycling fuel control (closed-loop) O2 signal is what the technician sees on the scope when probing at the O2 sensor signal wire.

The newer “wide band” O2 sensor solves the narrow sensing problem of the previous Zirconium sensors. These sensors are often called by different names such as, continuous lambda sensors, AFR (air fuel ratio sensors), LAF (lean air fuel sensor) and wide range O2 sensor. Regardless of the name, the principle is the same, which is to put the ECM in a better position to control the air/fuel mixture. In effect, the wide range O2 sensor can detect the exhaust’s O2 content way bellow or above the perfect 14.7:1 air/fuel ratio. Such control is needed on new lean burning engines with extremely low emission output levels. The tighter emission regulations are actually driving this newer fuel control technology and in the process making the systems much more complex and difficult to diagnose.

The wide range O2 sensor looks similar in appearance to the regular Zirconium O2 sensor. Its inner construction and operation are totally different, however . The Wide band O2 sensor is composed of a dual inner layer called “Reference cell” and “Pump cell”. The ECM’s AFR sensor circuitry always tries to keep a perfect air/fuel ratio (14.7:1) inside a special monitoring chamber (Diffusion Chamber or pump-cell circuit) by way of controlling its current. The AFR sensor uses dedicated electronic circuitry to set a pumping current in the sensor’s pump cell. In other words, if the air/fuel mixture is lean, the pump cell circuit voltage momentarily goes low and the ECM immediately regulates the current going through it in order to maintain a set voltage value or stoichiometric ratio inside the diffusion chamber. The pump cell then discharges the excess oxygen through the diffusion gap by means of the current flow created in the pump-cell circuit. The ECM senses the current flow and widens injector pulsation accordingly to add fuel.

If on the other hand the air/fuel mixture goes rich, the pump cell circuit voltage rapidly climbs high and the ECM immediately reverses the current flow polarity to readjust the pump cell circuit voltage to its set stable value. The pump-cell then pumps oxygen into the monitoring chamber by way of the reversed current flow in the ECM’s AFR pump-cell circuit. The ECM detects the reversed current flow and an injector pulsation-reduction command is issued bringing the mixture back to lean. Since the current flow in the pump cell circuit is also proportional to the oxygen concentration or deficiency in the exhaust, it serves as an index of the air/fuel ratio. The ECM is constantly monitoring the pump cell current circuitry, which it always tries to keep at a set voltage. For this reason, the techniques used to test and diagnose the regular Zirconium O2 sensor can not be used to test the wide band AFR sensor. These sensors are current devices and do not have a cycling voltage waveform. The testing procedures, which we will go into further along, are quite different from the older O2 sensors.

The AFR sensor operation can be thought of as being similar to the hot wire MAF sensor. But, instead of a MAF hot wire, the ECM tries to keep a perfectly stoichiometric air/fuel ratio inside the monitoring chamber by varying the pump cell circuit current. The sensing part, at the tip of the sensor, is always held at a constant voltage (depending on manufacturer). If the mixture goes rich, the ECM will adjust the current flowing through the sensing tip or pump cell circuit until the constant operating voltage level is achieved again. The voltage change actually happens very fast. The current flow through the pump circuit also pushes along the Oxygen atoms either into or out of the diffusion chamber (monitoring chamber) which restores the monitoring chamber’s air/fuel ratio to stoichiometry. Although the ECM varies the current, it tries to maintain the pump circuit at a constant voltage potential. As the ECM monitors the varying current, a special circuit (also inside the ECM) converts the current flow into a voltage value and passes it on to the serial data stream as a scanner PID. This is why the best way to test an AFR sensor’s signal is by monitoring the voltage conversion circuitry, which the ECM sends out as an AFR-voltage PID. It is possible to actually monitor the actual AFR sensor varying current, but the changes are very small (in the low mA range) and difficult to monitor. A second drawback to a manual AFR current test is that the actual signal wire has to be cut or broken to connect the amp-meter in series with the pump circuit. Today’s average clamp-on amp-meter is not accurate enough at such a small scale. For this reason, the easiest (but not the only) way to test an AFR sensor is with the scanner.

Another major difference between the wide range AFR sensor and a Zirconium O2 sensor is that it operates at above 1200 Deg. F (600 C). On these units the temperature is very critical and for this reason a special pulse-width controlled heater circuit is employed to precisely control the heater temperature. The ECM controls the heater circuit.

The wide operating range coupled with the inherent fast acting operation of the AFR sensor puts the system always at stoichiometry, which reduces a great deal of emissions. With this type of fuel control, the air/fuel ratio is always hovering close to 14.7:1. If the mixture goes slightly rich the ECM adjusts the pump circuit’s current flow to maintain the set operating voltage. The current flow is detected by the ECM’s detection circuit, with the result of a command for a reduction in injector pulsation being issued. As soon as the A/F mixture changes back to stoichiometry, because of the reduction in injector pulsation, the ECM will adjust the current respectively. The end result is NO current flow (0.00 Amps) at 14.7:1 A/F ratio. In this case a light negative hump is seen on the Amp-meter with the reading returning to 0.00 almost immediately. The fuel correction happens very quickly.

Toyota among others has always been a strong supporter of wide-range AFR sensor technology. The OBD II regulation calls for an O2 sensor voltage range from 0.00 to 1.00 volt. In order to meet the OBD II regulation, Toyota rearranged the AFR sensor PIDs (from the detection circuitry) by dividing their original OEM PID value by 5. The newer generic OBD II AFR sensor PID ranges between 0.48 (rich) and 0.80 (lean).

The following summarizes the wide-range AFR sensor operation. The Toyota AFR sensor is used here as an example, since the operating voltages change from one manufacturer to another.

• The AFR sensor operates at a much wider air/fuel ratio detection range. Hence the name wide range.• The AFR sensor provides the ECM with a signal value throughout a broad (wide) range of air/fuel ratios.• The ECM current detection circuit voltage (scanner PID) is totally the opposite of a regular Zirconium O2 sensor. The higher the voltage, the leaner the mixture and vise-versa.• The detection circuit voltage signal (scanner PID) output is proportional to the current flow applied by the ECM to the pump cell circuit (to keep the operating voltage) and an indicator of the air/fuel ratio. • In AFR sensor fuel control systems, the ECM can more accurately measure the actual air/fuel ratio on a wider scale. This allows the ECM to adjust to stoichiometry much faster.• With AFR sensor systems, the ECM does not cycle (rich/lean) as in the older Zirconium type O2 sensor. The output bias or pump cell circuit current detection voltage is fairly stable.• With the mixture at 14.7:1, the AFR sensor pump cell circuit current flow is 0.00 mA.• The pump cell circuit current flow changes polarity (by polar).• A rich mixture produces a negative current flow in the pump cell circuit.• A lean mixture produces a positive current flow in the pump cell circuit.• Because the current can flow in either direction, the AFR’s ground is NOT chassis ground. The AFR sensor uses a floating or ECM ground, which could be held at a specific voltage level above chassis ground (according to the manufacturer). Some manufacturers call this circuit (Signal -).• The actual pump cell circuit current flow pushes Oxygen atoms into or out of the diffusion chamber, depending on the direction of the current flow.• The detection circuit always monitors the direction of the current flow and how much of it is flowing.• Toyota AFR systems show an AFR PID of 3.30 volts at 14.7:1 A/F ratio. Each manufacturer uses a different PID voltage value to signal the stoichiometric point. Toyota also divides its OEM PID by 5 in order to arrive at an OBD II compliant voltage value.• The leaner the mixture, the higher the detection circuit voltage value (scanner PID). The richer the mixture the lower the detection circuit voltage value (scanner PID).• The ECM tries to maintain a stable voltage level across the AFR’s sensing tip or pump cell circuit.• The AFR voltage reading on the scanner is not the actual voltage across the AFR sensor pump cell. The AFR detection circuit (inside the ECM) generates the scanner PID voltage data from the pump cell current flow. The pump cell voltage is kept at a stable value by the ECM.• Wide-range AFR sensors are current devices and do not put out an actual voltage for their signal.• The current output signal flowing through the AFR circuit is in the mA range and can not be measured with a clamp-on amp-meter.• The same factors that affect the Zirconium O2 sensor also affect the AFR sensor (contamination, vacuum leaks, EGR failure, heater failure, etc).• The AFR’s heater operation is very critical to the sensor operation. These sensors operate at a much higher temperature than Zirconium sensors.• The AFR heater is pulse-width modulated by the ECM to maintain a stable temperature.• The AFR sensor heater is usually ON (pulsing) under normal driving conditions.• The AFR heater carries more current because of the higher temperatures necessary. For this reason the connections are more critical so as to avoid resistance in the circuit.• The AFR heater circuit carries up to 8 Amps compared to the Zirconium O2 sensor at 1.5 to 2 Amps

These sensors also have the added advantage of being able to have the fuel control system adjust to any desired air/fuel ratio other than 14.7:1 (Stoichiometry) or lambda 1. This option is especially important in new fuel control concepts such as lean-burn engines, where the engine’s fuel control changes at cruising speeds from 14.7:1 to a much leaner 19.0:1 or even higher. The result is tremendous reduction in emissions and fuel consumption. It is also worth stating that these leaner engines require special catalytic converter units capable of reducing the considerable amounts of NOx generated at such leaner (high temperature) mixtures.

References

* [http://www.autodiagnosticsandpublishing.com/Automotive%20Books.htm Diagnostics Strategies of Modern Automotive Systems]
* [http://www.bosch.com.au/content/language1/html/2534.htm Bosch Automotive Super Manual]


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • Oxygen sensor — Contents 1 Automotive applications 1.1 Function of a lambda probe 1.2 The probe …   Wikipedia

  • Air-fuel ratio — (AFR) is the mass ratio of air to fuel present during combustion. When all the fuel is combined with all the free oxygen, typically within a vehicle s combustion chamber,the mixture is chemically balanced and this AFR is called the stoichiometric …   Wikipedia

  • MegaSquirt — is the registered trademark of an aftermarket electronic fuel injection (EFI) controller designed to be used with a wide range of spark ignition internal combustion engines (i.e., not diesel engines.) It is a complete standalone fuel injection… …   Wikipedia

  • United States Air Force Security Forces — Security Forces Badge Active As Military Police (1942 1948) …   Wikipedia

  • EC-121 Warning Star — infobox Aircraft name = EC 121 Warning Star type = Airborne early warning aircraft manufacturer =Lockheed caption =WC 121N variant of VW 4 Hurricane Hunters designer = first flight = introduced = 1955 retired = 1982 (USAF) primary user = United… …   Wikipedia

  • Hard disk drive — Hard drive redirects here. For other uses, see Hard drive (disambiguation). Hard disk drive Mechanical interior of a modern hard disk drive Date invented 24 December 1954 [1] …   Wikipedia

  • Nitrous — is an often used abbreviation for the chemical compound nitrous oxide (N2O) also referred to as NOS. The term NOS is derived from the abbreviation of the company name Nitrous Oxide Systems (NOS), one of the pioneering companies in the development …   Wikipedia

  • Velocity air meter — A Velocity air meter measures the force of air rushing into an engine against a spring loaded door in an air tunnel. A linear potentiometer rotated along with the hinge of the air door measures the angle of the opening and sends an electrical… …   Wikipedia

  • Abkürzungen/Luftfahrt — Dies ist der erste Teil einer Liste der Abkürzungen und Akronyme, wie sie in der Luftfahrt und Militärluftfahrt verwendet werden. Liste der Abkürzungen Teil 1 A A (AA; AB; AC; AD; AE; AF; AG; AH; AI; AK; AL; AM; AN; AO; AP; AQ; AR …   Deutsch Wikipedia

  • Nitrous oxide engine — This page discusses the use of nitrous oxide in a racing context. For other uses, see Nitrous oxide. Dragster in near lane is purging nitrous oxide Nitrous oxide (N2O) is a chemical compound used as an oxidizing agent to increase an internal… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”